Pre Action Fire Sprinklers

Newark, Jersey City, Paterson & Elizabeth Pre Action Fire Sprinklers

Whenever you are concerned with an accidental fire sprinkler discharge such as rare, precious, computers or valuables that may be damaged when wet; the pre action fire sprinkler system may be the choice for fire prevention and fire protection. There are two main types of pre action fire sprinkler systems that can be installed in Newark, Jersey City, Paterson & Elizabeth.

Always work with actively State licensed fire sprinkler companies, contractor and/or fire safety engineers in Newark, Jersey City, Paterson & Elizabeth to perform any installation, service, maintenance, repair, design, engineering, remodel, retrofit, tests or inspections that may be required to comply with fire codes, rules and regulations.

Newark, Jersey City, Paterson & Elizabeth Pre Action Fire Sprinklers

Newark, Jersey City, Paterson & Elizabeth Fire Sprinkler Tests & Inspections


Single Interlock Pre Action Fire Sprinklers

Single interlock pre action fire sprinkler systems generally are activated by a heat detector, smoke detector, or fire alarm. The pre action system activates and fills the fire sprinkler pipes with water and sprays the water from the fire sprinkler heads. The desired effect is to essentially convert a dry pipe fire sprinkler system into a wet pipe fire sprinkler system. If any air pressure is lost in the pre action fire sprinkler system a trouble alarm generally alerts you of the issues.

Double Interlock Pre Action Fire Sprinkler Systems

Double interlock pre action fire sprinkler systems generally are activated by a heat detector, smoke detector, or fire alarm. The double interlock pre action system activates and fills the fire sprinkler pipes with water and sprays the water from the fire sprinkler heads. The desired effect is to essentially convert a dry pipe fire sprinkler system into a wet pipe fire sprinkler system. If any air pressure is lost in the pre action fire sprinkler system a trouble alarm generally alerts you of the issues. The main difference is that all fire sprinkler heads remain open similar to a deluge fire sprinkler system.

Newark, Jersey City, Paterson & Elizabeth Fire Sprinkler Tests & Inspections

NFPA 13D has created a standard for the installation of fire sprinkler systems, detailing information for the combined dry pipe and pre action system. “1.1* Scope. 1.1.1 This standard shall cover the design, installation, and maintenance of automatic sprinkler systems for protection against the fire hazards in one- and two-family dwellings and manufactured homes. 1.1.2 This standard assumes that the sprinkler system is designed to protect against a fire originating from a single ignition location.”
Newark, Jersey City, Paterson & Elizabeth Fire Protection Company
Newark, Jersey City, Paterson & Elizabeth Fire Prevention and Safety Fire Protection Service
New York City Fire Protection Company
Newark, Jersey City, Paterson & Elizabeth Fire Sprinklers
Newark, Jersey City, Paterson & Elizabeth Fire Protection Service
Emergency Fire Protection
Service Available
Install, Service & Repair
Fire Service Pro LLC
Newark, Jersey City, Paterson & Elizabeth Amerex Fire Extinguishers Newark, Jersey City, Paterson & Elizabeth Brooks Fire Protection Equipment

No comments:

Post a Comment